4ID1XX/XX is a double panel digital indicator (dimensions: 72 x 144 mm) with four inputs and displays designed to meet the customer’s needs. It’s possible to request the digital indicator with two inputs of your choice in the range of the ESAM range in 3, 3 ½ or 4 digit formats. 4ID1XX/XX is the ideal solution for any type of system, application or panel where there is a need to display two measures with precision (accuracy class 0,2% or 0,5%) and reliability. The ESAM digital indicators allow you to set a series of useful functions such as: arbitrary scaling of the measurement, sign suppression, hold function, alternative scaling, decimal point position, etc. The instrument’s auxiliary power supply allows it to be used both in systems powered by mains voltage, thanks to an extended range power supply 60 … 265Vac / 80 … 300Vdc, and in systems powered at low voltage by having a extended range 12 … 60 Vac – 12 … 80Vdc (option). Ask to our technical support the digital indicator that meets your needs.

How to order: Dial the code of each instrument according to the desired number and type of measurement using the datasheets as reference. For example, double digital instrument 72×144 with the measures of: alternating voltage and three alternating currents ID33002 + ID33004 + ID33004 + ID33004 code: 4ID13002/004/004/004

Multiple digital indicator with four displays according to your needs – 72×144

  • Accuracy: 0,2% or 0,5%
  • Inputs: 3 – 3 ½ – 4 cifre
  • Insulation: 2kV

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E101A

    Single-phase network analyzer for DIN rail with RS485 ModBus RTU serial interface and analog outputs

     

    • Single-phase 10A
    • Accuracy 0,2% of f.s.
    • RS485 ModBus RTU serial interface
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc 
  • ESK 61.4

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 44 mm
    • bus bar dimension: 63 x 10 mm
    • Range: 400 … 1500A
  • VN6-N

    Measuring voltage transformer with 2 isolated poles

    • Accuracy: 0,5%
    • Burden: 6VA
    • Range: 100 … 600V

You may also like…

  • M901-M

    Front panel (96×96 mm) multifunction meter, single-phase connection with RS485 ModBus RTU serial interface

    • Single-phase with display
    • Accuracy 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two alarms outputs
    • Touch buttons

     

  • ETP1043U3

    HMI touch panel – 4,3″ with ModBus RTU and ModBus TCP/IP interfaces

    • Touch panel
    • RS485 ModBus RTU
    • ModBus TCP/IP su Ethernet
    • Aux. power supply 12…36Vdc
    • Software PLC on board

     

     

     

  • E742002AN-1

    Digital indicator with 14 analog inputs – 72×144 – with ALARMS

    • Accuracy: 0,5%
    • Inputs:  0 … ±10V – 0 … ±5V – 0 … ± 60mV
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Alarms outputs