Catalogo

  • ID93501-20…25

    Digital indicator for analog process signals (direct voltage) – 96×96 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV

     

     

  • IDM3003-40…45

    Digital indicator for analog process signals (direct current) – 4 DIN MODULES – 3 digits

    • Accuracy: 0,2%
    • Input: ± 999
    • Insulation: 2kV
    • Span adjustment

     

  • M403-RM

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface

    • Three-phase with display
    • Accuracy: 0,2%
    • Input from Rogowski coil
    • RS485 ModBus RTU serial interface
    • Two alarms outputs

     

     

  • E102TC-2iE

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E96VT

    Analog varmeter for A.C. signals – 96×96 with accessory –  4 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E96WT

    Analog wattmeter for A.C. signals – 96×96 with accessory –  4 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • ER8

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 2 x 30 mm
    • Bus bar dimension: 82 x 32 mm
    • Range: 300 … 3200A
  • ID33501-40…45

    Digital indicator for analog process signals (direct voltage) – 72×36 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV
    • Span adjust
  • ID43501-40…45

    Digital indicator for analog process signals (direct voltage) – 96×48 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV
    • Span adjust
  • ID73501-40…45

    Digital indicator for analog process signals (direct voltage) – 72×72 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV
    • Span adjust
  • ID93501-40…45

    Digital indicator for analog process signals (direct voltage) – 96×96 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV
    • Span adjust
  • IDM3003-60…65

    Digital indicator for analog process signals (direct current) – 4 DIN MODULES – 3 digits

    • Accuracy: 0,2%
    • Input: ± 999
    • Insulation: 2kV
    • Span adjustment
    • Settable decimal point and full scale 
1 2 3 54 55 56 57 58 59 60 61