Catalogo

  • M403-RE

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface

    • Single-phase with display
    • Accuracy: 0,2%
    • Input from Rogowski coil
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two alarms outputs
  • E104TC

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • ER8V

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 2 x 35 mm
    • Bus bar dimension: 37 x 80 mm
    • Range: 400 … 2500A
  • ID33503-20…25

    Digital indicator for analog process signals (direct current) – 72×36 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV

     

     

  • ID43503-20…25

    Digital indicator for analog process signals (direct current) – 96×48 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV

     

     

  • ID73503-20…25

    Digital indicator for analog process signals (direct current) – 72×72 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV

     

     

  • ID93503-20…25

    Digital indicator for analog process signals (direct current) – 96×96 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV

     

     

  • IDM3501-20…25

    Digital indicator for analog process signals (direct voltage) – 4 DIN MODULES – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV

     

     

  • M403-RBL

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface

    • Three-phase without display
    • Accuracy: 0,2%
    • Input from Rogowski coil
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two alarms outputs
  • E104TC-E

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • ER12

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 2 x 50 mm
    • Bus bar dimension: 127 x 57 mm
    • Range: 500 … 3500A
  • ID33503-42…45

    Digital indicator for analog process signals (direct current) – 72×36 – 3 ½ digits

    • Accuracy: 0,2%
    • Input: ± 1999
    • Insulation: 2kV
    • Span adjust
1 2 3 55 56 57 58 59 60 61