  • E104PD

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Two digital inputs: NPN – PNP – Namur – Impulsi – Effetto hall – Encoder
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E104PD-E

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two digital inputs: NPN – PNP – Namur – Impulsi – Effetto hall – Encoder
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104PD-2i

    DIN rail I/O module for analogand digital signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Two inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two insulated analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104PD-2E

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104PD-2iE

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two insulated analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc