3.5 Modules for pid regulation - RS485 - ethernet

Showing 1–12 of 15 results

  • E102Pid

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc 
  • E102Ptid

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102Pid-E

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Ptid-E

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Pid-2i

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Ptid-2i

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc 
  • E102Pid-2E

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface and ModBus TCP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc 
  • E102Ptid-2E

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc 
  • E102Pid-2iE

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface and ModBus TCP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Ptid-2iE

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102TCid

    DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs from thermocouples: types J – K – R – S – T – B – E – N
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E102TCid-E

    DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs from thermocouples: types J – K – R – S – T – B – E – N
    • Analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
1 2