ID34001 is a 4 digits digital panel indicator (dimensions: 72 x 36 mm) suitable for reading a direct voltage. Depending on the model (see data sheet) it’s possible to read signals from ± 99.99mV up to ± 9999 V (from divider). ID34001 is the ideal solution for any type of system, application or panel where there is a need to display a direct voltage with precision (accuracy class 0,2%) and reliability. The ESAM digital indicators allow you to set a series of useful functions such as: arbitrary scaling of the measurement, sign suppression, hold function, alternative scaling, decimal point position, etc. The instrument’s auxiliary power supply allows it to be used both in systems powered by mains voltage, thanks to an extended range power supply 60 … 265Vac / 80 … 300Vdc, and in systems powered at low voltage by having a extended range 12 … 60 Vac – 12 … 80Vdc (option).

Range types for models:

ID34001-02   ± 99.99mV ID34001-03   ± 999.9mV ID34001-04   ± 9.999V ID34001-05   ± 99.99V ID34001-06   ± 600.0V ID34001-DP   ± 9999V (from divider)

Digital indicator for direct voltage – 72×36 – 4 digits

  • Accuracy: 0,2%
  • Input: ± 99.99mV … ± 9999V
  • Insulation: 2kV

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E101P

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • MT-Vdc

    DIN rail transducer for D.C. voltage – aux. power supply execution

    • One channel 500V max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulaion 2kV

     

  • PR-1

    Voltage divider

    • Continuous overload: 1,2 Vn
    • Range: 600 … 2000V

You may also like…

  • SID72MP1

    Digital indicator for direct voltage – 72×72 – 4 digits with ALARMS

    • Accuracy: 0,2%
    • Input: ± 19.99mV … ± 1999V
    • Insulation: 2kV
  • E742002AN-1

    Digital indicator with 14 analog inputs – 72×144 – with ALARMS

    • Accuracy: 0,5%
    • Inputs:  0 … ±10V – 0 … ±5V – 0 … ± 60mV
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Alarms outputs
  • 2ID7XX/XX

    Multiple digital indicator with two displays according to your needs – 72×72

    • Accuracy: 0,2% or 0,5%
    • Inputs: 3 – 3 ½ – 4 cifre
    • Insulation: 2kV