  • SIDM4MP5

    Digital indicator for resistance measurement – dimensions 4 mod.- 4 digits with  ALLARMI

    • Accuracy: 0,2%
    • Input:19.99Ω …  1.999MΩ
    • Insulation: 2kV
  • SIDM4MP6

    Digital indicator for frequency – 4 DIN MODULES – 4 digits with ALARMS

    • Accuracy: 0,2%
    • Input: 9.999Hz … 9.999kHz
    • Insulation: 2kV
  • SIDM4MP7

    Digital indicator for temperature measurement – dimensions 4 mod. – 4 digits with  ALLARMI

    • Accuracy: 0,5%
    • Input: -60 … +600°C
    • Insulation: 2kV
  • SIDM4MP8

    Digital indicator for tachometric frequency – dimensions 4 mod.- 4 digits with  ALLARMI

    • Accuracy: 0,5%
    • Input:  199,9 rpm…1999 rpm
    • Insulation: 2kV
  • T-BUS

    Accessory for T-BUS connection

    • Compatible with all products in the E10X series
  • VN6 (while stock lasts)

    Measuring voltage transformer with 2 isolated poles

    • Accuracy: 0,5%
    • Burden: 6VA
    • Range: 100 … 600V
  • BC550-PRT

    End-line test bench for electric motors

    • Accuracy: 0,5% del fondo scala
    • Display: touch panel
    • Aux. power supply: 230Vac 50/60Hz

     

     

  • E101P-E

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E101U-E

    DIN rail I/O universal module with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • A configurable input: analog signal – temperature sensor – resistance
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102P-E

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Pid-E

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Pt-E

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     