Catalogo

  • E102Ptid-E

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102R-E

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: resistances or potentiometers
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104PD-E

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two digital inputs: NPN – PNP – Namur – Impulsi – Effetto hall – Encoder
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E106D-E

    DIN rail I/O module for digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E48PY

    Analog cosphimeter for A.C. signals – 48×48 with accessory – 3 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Input: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Range: 0.5 lead / 1 / 0.5 lad (others on request)
    • Scale: 90°
  • E48VY

    Analog varmeter for A.C. signals – 48×48 with accessory –  3 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E48WY

    Analog wattmeter for A.C. signals – 48×48 with accessory –  3 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E72FP

    Analog frequency-meter for A.C. signals – 72×72

    • Accuracy: 1,5%
    • Input: 100V … from VT xx/ 100V 
    • Range: 45 … 55Hz – 55 … 65Hz – 45 … 65Hz (others on request)
    • Scale: 90°

     

  • E742002BOX

    Portable network analyzer

    • Accuracy: 0,5% of full scale
    • Display: digital with autorange
    • RS485 ModBus RTU Serial interface
    • Two settabe relays outputs
    • Aux. power supply: 230Vac 50/60Hz

     

  • ANALIZZATORI DI RETE DA PANNELLO

    E92001SE

    Front panel (96 x 96 mm) network analyzer for three-phase (3-4 wires or ARON) connection – without energies

    • Three-phase with display
    • Accuracy 0,5% of f.s.

     

     

  • EA10

    Split core current transformer

    • Accuracy: 0,5%
    • Cable dimension: 90 mm
    • Range: 500 … 2000A
  • EN5-N

    Measuring voltage transformer with one isolated pole

    • Accuracy: 0,5%
    • Burden: 5VA
    • Range: 100:√3 … 600:√3V
1 2 3 30 31 32 33 34 35 36 59 60 61