Catalogo

  • E102Ptid-2i

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc 
  • E102R-2i

    DIN rail I/O module for resistnces or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: resistances or potentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104PD-2i

    DIN rail I/O module for analogand digital signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Two inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two insulated analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E106D-2i

    DIN rail I/O module for digital signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two insulated analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E1200BOX

    Portable precision network analyzer

    • Accuracy: 0,2% of reading
    • Display: digital with touch panel
    • RS485 ModBus RTU and ModBus TCP/IP interfaces
    • Aux. power supply: 230Vac 50/60Hz
  • E48PS

    Analog cosphimeter for A.C. signals – 48×48 with accessory – 4 wires THREE-PHASE conection

    • Accuracy: 1,5%
    • Input: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Range: 0.5 lead / 1 / 0.5 lad (others on request)
    • Scale: 90°
  • E48VD

    Analog varmeter for A.C. signals – 48×48 with accessory –  3 wires THREE-PHASE connection (ARON)

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E48WD

    Analog wattmeter for A.C. signals – 48×48 with accessory –  3 wires THREE-PHASE connection (ARON)

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E92002

    Front panel (96 x 96 mm) network analyzer for three-phase (3-4 wires or ARON) connection

    • Three-phase with display
    • Accuracy 0,5% of f.s.
    • RS485 ModBus RTU Serial interface
    • Two alarms outputs
  • E96FP

    Analog frequency-meter for A.C. signals – 96×96

    • Accuracy: 1,5%
    • Input: 100V … from VT xx/ 100V 
    • Range: 45 … 55Hz – 55 … 65Hz – 45 … 65Hz (others on request)
    • Scale: 90°

     

  • EBU23

    Split core current transformer

    • Accuracy: 3% o 1%
    • Bus bar dimension: 20 x 30 mm
    • Range 100 … 400A
  • EN10 (while stock lasts)

    Measuring voltage transformer with one isolated poles

    • Accuracy: 0,5%
    • Burden: 10VA
    • Range: 100:√3 … 1000:√3V
1 2 3 33 34 35 36 37 38 39 59 60 61