Showing 421–432 of 724 results
-
E102Ptid-2i
DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs with PID control
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102R-2i
DIN rail I/O module for resistnces or potentiometers with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two inputs: resistances or potentiometers
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104PD-2i
DIN rail I/O module for analogand digital signals with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two analog inputs
- Two inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
- Two insulated analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E106D-2i
DIN rail I/O module for digital signals with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
- Two insulated analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E1200BOX
Portable precision network analyzer
- Accuracy: 0,2% of reading
- Display: digital with touch panel
- RS485 ModBus RTU and ModBus TCP/IP interfaces
- Aux. power supply: 230Vac 50/60Hz
-
E48PS
Analog cosphimeter for A.C. signals – 48×48 with accessory – 4 wires THREE-PHASE conection
- Accuracy: 1,5%
- Input: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Range: 0.5 lead / 1 / 0.5 lad (others on request)
- Scale: 90°
-
E48VD
Analog varmeter for A.C. signals – 48×48 with accessory – 3 wires THREE-PHASE connection (ARON)
- Accuracy: 1,5%
- Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Scale: 90°
-
E48WD
Analog wattmeter for A.C. signals – 48×48 with accessory – 3 wires THREE-PHASE connection (ARON)
- Accuracy: 1,5%
- Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Scale: 90°
-
E92002
Front panel (96 x 96 mm) network analyzer for three-phase (3-4 wires or ARON) connection
- Three-phase with display
- Accuracy 0,5% of f.s.
- RS485 ModBus RTU Serial interface
- Two alarms outputs
-
E96FP
Analog frequency-meter for A.C. signals – 96×96
- Accuracy: 1,5%
- Input: 100V … from VT xx/ 100V
- Range: 45 … 55Hz – 55 … 65Hz – 45 … 65Hz (others on request)
- Scale: 90°
-
EBU23
Split core current transformer
- Accuracy: 3% o 1%
- Bus bar dimension: 20 x 30 mm
- Range 100 … 400A
-
EN10 (while stock lasts)
Measuring voltage transformer with one isolated poles
- Accuracy: 0,5%
- Burden: 10VA
- Range: 100:√3 … 1000:√3V