Catalogo

  • E102R-2E

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: resistances or potentiometers
    • Two analog outputs (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104PD-2E

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E106D-2E

    DIN rail I/O module for digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E48VS

    Analog varmeter for A.C. signals – 48×48 with accessory –  4 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E48WS

    Analog wattmeter for A.C. signals – 48×48 with accessory –  4 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E72PS

    Analog cosphimeter for A.C. signals – 72×72 with accessory – SINGLE-PHASE connection

    • Accuracy: 1,5%
    • Input: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Range: 0.5 lead / 1 / 0.5 lad (others on request)
    • Scale: 90°
  • EBU58

    Split core current transformer

    • Precisione 1%
    • Passaggio barra 50 x 80 mm
    • Portate 250 … 800A
  • EN10-N

    Measuring voltage transformer with one isolated pole

    • Accuracy: 0,5%
    • Burden: 10VA
    • Range: 100:√3 … 1000:√3V
  • ESK 41.4

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 32 mm
    • Bus bar dimension: 40 x 10 mm
    • Range: 250 … 800A
  • ESO

    Summing current transformer

    • Accuracy: 0,5%
    • 2, 3 or 4 channels
  • EWSK 31.5

    Primary wound current transformer

    • Accuracy: 0,5%
    • Range: 50 … 150A
  • ICE 0101 B

    Digital multimeter with auto-range

    • Display: 3 3/4 digit
    • Power supply: 2 x 1,5V batteries
1 2 3 36 37 38 39 40 41 42 59 60 61