Catalogo

  • PF72M

    Analog voltmeter for D.C. signals – 72×24

    • Accuracy: 1,5%
    • Inputs: 60mV … 600V
    • Range: according to your needs
  • R9L

    Analog voltmeter for A.C. signals – dimensions 90×80

    • Accuracy: 1,5%
    • Input:  6V … from VT xx/ 100V
    • Range: according to your needs
  • SID8MP-TC

    Digital indicator for high precision thermocouple measurements – dimensions 96×48  – 8 digits with ALARMS

    • Accuracy: 0,1%
    • Input:   99999999
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Analog output
  • SID98MPT

    Digital indicator (INTEGRATOR / TOTALIZER) for high precision process signals – 96×96 format – 8 digits with ALARMS

    • Accuracy 0,1%
    • Input:   99999999
    • Integrated measurement
    • Insulation 2kV
    • RS485 ModBus RTU serial interface
    • Analog output
  • VN10-N

    Measuring voltage transformer with 2 isolated poles

    • Accuracy: 0,5%
    • Burden: 10VA
    • Range: 100 … 1000V
  • D3CE

    Analog ammeter for A.C. signals – 3 DIN mod.

    • Accuracy: 1,5%
    • Input:  1A … from CT / 5A
    • Scale: 90°
  • D3CM

    Analog ammeter for D.C. signals – 3 DIN mod.

    • Accuracy: 1,5%
    • Input: 50uA … 10 A from SHUNT / 60mV
    • Scale: 90°
  • D3CM

    Analog voltmeter for D.C. signals – 3 DIN modules

    • Accuracy: 1,5%
    • Input: 60mV … 600 V from divider xxV / 100V
    • Scale: 90°
  • E101P-2E

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog outputs (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E101U-2iE

    DIN rail I/O universal module with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • A configurable input: analog signal – temperature sensor – resistance
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102P-2iE

    DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Pid-2iE

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface and ModBus TCP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
1 2 3 38 39 40 41 42 43 44 59 60 61