Catalogo

  • E101P

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E101U

    DIN rail I/O universal module with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • A configurable input: analog signal – temperature sensor – resistance
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102P

    DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102Pid

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc 
  • E102Pt

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E102Ptid

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102R

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: resistances or potentiometers
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E104PD

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Two digital inputs: NPN – PNP – Namur – Impulsi – Effetto hall – Encoder
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E106D

    DIN rail I/O module for digital signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E1100

    High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection

     

    • Three-phase 3-4 eires or ARON
    • Accuracy 0,2% of reading (from 5 to 100% of f.s.)
    • RS485 ModBus serial interface
    • Harmonic analysis up to 64° harmonic

     

  • E1200

    High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection

    • Three-phase 3-4 eires or ARON
    • Accuracy 0,2% of reading (from 5 to 100% of f.s.)
    • RS485 ModBus serial interface
    • ModBus TCP/IP on Ethernet (with web server) 
    • Energies measures
    • Harmonic analysis up to 64° harmonic
  • E2001

    Rear panel network analyzer for three-phase (3-4 wires or ARON) connection

    • Three-phase with display
    • Accuracy 0,5% of f.s.

     

     