E1200 is a DIN rail network analyzer suitable for measuring electrical parameters of an A.C. three-phase line in all configurations (3 or 4 wires or ARON). It is powered by a separate voltage (galvanically isolated) and has a current input capable of measuring from 0.05 to 5 A direct or by CT / 5A or / 1A and external VT. It’s equipped with a RS485 Modus RTU serial output and an Ethernet output with ModBus TCP/IP protocol (with Web Server) which allows remote monitoring of all measurement and configuration parameters. The E1200 analyzer is the ideal instrument for all those applications where it’s essential to have measurements (voltages, currents, active – reactive – apparent powers, power factor, etc.) with high accuracy (0.2% of reading) and reliability. For this reason our analyzer is increasingly used in applications with high technological content, such as: test benches, high precision acquisition systems, management of complex plants, production plants using renewable sources, etc. Furthermore, the analyzer guarantees optimal operation even in distorted mains conditions and frequency outside the 50-60 Hz range. The E1200 network analyzer can also be connected to the E3000 module equipped with 3 analog outputs (4 … 20mA – 0 … 10mA – 0 … 5mA – 0 … 10V etc.) which can be associated with the measurements made by the analyzer to repeat the measured signal to acquisition systems such as PLC, other instruments, industrial PCs etc.
High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection
- Three-phase 3-4 eires or ARON
- Accuracy 0,2% of reading (from 5 to 100% of f.s.)
- RS485 ModBus serial interface
- ModBus TCP/IP on Ethernet (with web server)
- Energies measures
- Harmonic analysis up to 64° harmonic
Data Sheet
User Manual
Catalog
Software
Recommended accessories…
You may also like…
-
M403-E
DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface
- Three-phase with display
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two alarms outputs
-
M401-E
DIN RAIL multifunction meter, single-phase connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface
- Single-phase with display
- Accuracy 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two alarms outputs
-
E1100
High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection
- Three-phase 3-4 eires or ARON
- Accuracy 0,2% of reading (from 5 to 100% of f.s.)
- RS485 ModBus serial interface
- Harmonic analysis up to 64° harmonic