E1100 is a DIN rail network analyzer suitable for measuring electrical parameters of an A.C. three-phase line in all configurations (3 or 4 wires or ARON). It is powered by a separate voltage (galvanically isolated) and has a current input capable of measuring from 0.05 to 5 A direct or by CT / 5A or / 1A and external VT. It’s equipped with a RS485 Modus RTU serial output which allows remote monitoring of all measurement and configuration parameters. The E1100 analyzer is the ideal instrument for all those applications where it’s essential to have measurements (voltages, currents, active – reactive – apparent powers, power factor, etc.) with high accuracy (0.2% of reading) and reliability. For this reason our analyzer is increasingly used in applications with high technological content, such as: test benches, high precision acquisition systems, management of complex plants, production plants using renewable sources, etc. Furthermore, the analyzer guarantees optimal operation even in distorted mains conditions and frequency outside the 50-60 Hz range.

High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection

 

  • Three-phase 3-4 eires or ARON
  • Accuracy 0,2% of reading (from 5 to 100% of f.s.)
  • RS485 ModBus serial interface
  • Harmonic analysis up to 64° harmonic

 

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E-CONNECT

    Gateway RS485 ModBus RTU – ModBus ModBus TCP/IP

    • RS485 ModBus RTU Serial interface
    • ModBus TCP/IP on Ethernet
    • Aux. power supply: 18…48Vac/dc

     

  • EWSK 30

    Primary wound current transformer

    • Accuracy: 0,5%
    • Range: 10 … 20A
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc

You may also like…

  • M403-M

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface

     

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two alarms outputs

     

  • M403-E

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two alarms outputs
  • E1200

    High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection

    • Three-phase 3-4 eires or ARON
    • Accuracy 0,2% of reading (from 5 to 100% of f.s.)
    • RS485 ModBus serial interface
    • ModBus TCP/IP on Ethernet (with web server) 
    • Energies measures
    • Harmonic analysis up to 64° harmonic