Showing 553–564 of 724 results
-
E102TCid-E
DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two inputs from thermocouples: types J – K – R – S – T – B – E – N
- Analog outputs with PID control
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104P-E
DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four analog inputs
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104Pt-E
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104R-E
DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: resistances or potentiometers
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E72VY
Analog varmeter for A.C. signals – 72×72 with accessory – 3 wires THREE-PHASE connection
- Accuracy: 1,5%
- Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Scale: 90°
-
E72WY
Analog wattmeter for A.C. signals – 72×72 with accessory – 3 wires THREE-PHASE connection
- Accuracy: 1,5%
- Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Scale: 90°
-
E96PS
Analog cosphimeter for A.C. signals – 96×96 with accessory – SINGLE-PHASE connection
- Accuracy: 1,5%
- Input: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Range: 0.5 lead / 1 / 0.5 lad (others on request)
- Scale: 90°
-
EA26V
Split core current transformer
- Precisione 0,5%
- Passaggio cavo 4 x 35 mm
- Passaggio barra 2 x 125 x 5 mm
- Portate 1200 … 2500A
-
EV6
Measuring voltage transformer with 2 isolated poles
- Accuracy: 0,5%
- Burden: 6VA
- Range: 100 … 600V
-
ICE 5200 T
TRMS digital multimeter with auto-range
- Display: digital 6000 points
- Power supply: 2 x 1,5V batteries