SID98MP-P
Digital indicator for high precision potentiometer measurements – dimensions 96×96 – 8 digits with ALARMS
- Accuracy: 0,1%
- Input: 99999999
- Insulation: 2kV
- RS485 ModBus RTU serial interface
- Analog output
-
SIDM4MP3-20…25
Digital indicator for process signals (direct current) – dimensions 4 mod. – 4 digits with ALARMS
- Accuracy: 0,2%
- Input: ± 9999
- Insulation: 2kV
-
E102TCid-2i
DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two inputs from thermocouples : types J – K – R – S – T – B – E – N
- Two insulated analog outputs with PID control
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104P-2i
DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four analog inputs
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104Pt-2i
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104R-2i
DIN rail I/O module for resistnces or potentiometers with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four inputs: resistances or potentiometers
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E72VD
Analog varmeter for A.C. signals – 72×72 with accessory – 3 wires THREE-PHASE connection (ARON)
- Accuracy: 1,5%
- Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Scale: 90°
-
E72WD
Analog wattmeter for A.C. signals – 72×72 with accessory – 3 wires THREE-PHASE connection (ARON)
- Accuracy: 1,5%
- Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Scale: 90°
-
E96PY
Analog cosphimeter for A.C. signals – 72×72 with accessory – 3 wires THREE-PHASE connection
- Accuracy: 1,5%
- Input: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Range: 0.5 lead / 1 / 0.5 lad (others on request)
- Scale: 90°
-
EA28
Split core current transformer
- Precisione 0,5%
- Passaggio parra 4 x 120 x 10 mm
- Portate 1000 … 2500A
-
EV10
Measuring voltage transformer with 2 isolated poles
- Accuracy: 0,5%
- Burden: 10VA
- Range: 100 … 1000V