Catalogo

  • SID98MP-P

    Digital indicator for high precision potentiometer measurements – dimensions 96×96  – 8 digits with ALARMS

    • Accuracy: 0,1%
    • Input:   99999999
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Analog output
  • SIDM4MP3-20…25

    Digital indicator for process signals (direct current) – dimensions 4 mod. – 4 digits with ALARMS

    • Accuracy: 0,2%
    • Input: ± 9999
    • Insulation: 2kV
  • E102TCid-2i

    DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs from thermocouples : types J – K – R – S – T – B – E – N
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E104P-2i

    DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four analog inputs
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104Pt-2i

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E104R-2i

    DIN rail I/O module for resistnces or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four inputs: resistances or potentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E72VD

    Analog varmeter for A.C. signals – 72×72 with accessory –  3 wires THREE-PHASE connection (ARON)

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E72WD

    Analog wattmeter for A.C. signals – 72×72 with accessory –  3 wires THREE-PHASE connection (ARON)

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E96PY

    Analog cosphimeter for A.C. signals – 72×72 with accessory – 3 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Input: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Range: 0.5 lead / 1 / 0.5 lad (others on request)
    • Scale: 90°
  • EA28

    Split core current transformer

    • Precisione 0,5%
    • Passaggio parra 4 x 120 x 10 mm
    • Portate 1000 … 2500A
  • ESK 13.AN

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 2 x 50 mm
    • Bus bar dimension: 3 x 100 x 10 mm
    • Range: 2000 … 4000A
  • EV10

    Measuring voltage transformer with 2 isolated poles

    • Accuracy: 0,5%
    • Burden: 10VA
    • Range: 100 … 1000V