Showing 517–528 of 724 results
-
R55L
Analog ammeter for D.C. signals – dimensions 70×60
- Accuracy: 1,5%
- Input: 1mA … 5A
- Range: according to yor needs
-
RC-179
Rogowski Coil – internal diameter 179mm
- Accuracy 1%
- 100mV/kA
-
SID8MP-MV
Digital indicator for high precision mV measurements – dimensions 96×48 – 8 digits with ALARMS
- Accuracy: 0,1%
- Input: 99999999
- Insulation: 2kV
- RS485 ModBus RTU serial interface
- Analog output
-
SID98MPT-P
Digital indicator (INTEGRATOR / TOTALIZER) for high precision potentiometers signals – 96×96 format – 8 digits with ALARMS
- Accuracy 0,1%
- Input: 99999999
- Integrated measurement
- Insulation 2kV
- RS485 ModBus RTU serial interface
- Analog output
-
VN20 (while stock lasts)
Measuring voltage transformer with 2 isolated poles
- Accuracy: 0,5%
- Burden: 20VA
- Range: 100 … 1000V
-
D3CE
Analog votlmeter for A.C. signals – 3 DIN mod.
- Accuracy: 1,5%
- Input: 40 V … from VT xx/100V
- Scale: 90°
-
E101P-2iE
DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102TCid
DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two inputs from thermocouples: types J – K – R – S – T – B – E – N
- Analog output with PID control
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104P
DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four analog inputs
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104Pt
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104R
DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four inputs: resistances or potentiometers
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc