MT-CV256
DIN rail voltage and current transducer with high sampling – single phase insertion
- Single-phase 500V 10A max
- Accuracy 0,5%
- High sampling
- RS485 ModBus RTU Serial Interface
- Two analog outputs
- Insulation 4kV
-
MT-F
DIN rail frequency transducer for alternating current systems
- One channel 500V max
- Accuracy 0,5%
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 4kV
-
MT-FT
DIN rail frequency transducer for alternating current systems
- One channel from NAMUR, PNP, NPN, Push-pull, contact
- Accuracy 0,5%
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 2kV
-
MT-FV16
Transducer for photovoltaic strings
- 16 measurement channels
- 1 input for Pt100 temperature probe
- 3 digital inputs
- 1 digital output
- Accuracy < 0,5%
- Insulation 4kV
- RS485 Serial interface
-
MT-LF
DIN rail frequency transducer for alternating current systems
- One channel from NAMUR, PNP, NPN, Push-pull, contact
- Accuracy 0,5%
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 2kV
-
MT-PA1
DIN rail active power transducer – single phase connection
- Single-phase 500V 10A max
- Accuracy 0,5%
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 4kV
-
MT-PA256
DIN rail active power transducer with high sampling – single phase connection
- Single-phase 500V 10A max
- Accuracy 0,5%
- High sampling
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 4kV
-
MT-PA31
DIN rail active power transducer – balanced 3 wires three-phase connection
- Three-phase 500V 10A max
- Accuracy 0,5%
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 4kV
-
MT-PA32
DIN rail active power transducer – unbalanced 3 wires three-phase connection (ARON)
- Three-phase 500V 10A max
- Accuracy 0,5%
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 4kV
-
MT-PA41
DIN rail active power transducer – balanced 4 wires three-phase connection
- Three-phase 500V 10A max
- Accuracy 0,5%
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 4kV
-
MT-PA43
DIN rail active power transducer – unbalanced 4 wires three-phase connection
- Three-phase 500V 10A max
- Accuracy 0,5%
- RS485 ModBus RTU Serial Interface
- Analog output
- Insulation 4kV
-
MT-PACV256
DIN rail voltage, current and active power transducer with high sampling – single phase insertion
- Single-phase 500V 10A max
- Accuracy 0,5%
- High sampling
- RS485 ModBus RTU Serial Interface
- Three analog outputs
- Insulation 4kV