1 Electric measures and energy management

  • MT-PAR1

    DIN rail active and reactive power transducer – single phase connection

     

    • Single-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 4kV
  • MT-PAR256

    DIN rail active ad reactive power transducer with high sampling – single phase connection

    • Single-phase 500V 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 ModBus RTU Serial Interface
    • Two analog output
    • Insulation 4kV
  • MT-PAR31

    DIN rail active and reactive power transducer – balanced 3 wires three-phase connection

     

    • Three-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Two analog output
    • Insulation 4kV
  • MT-PAR32

    DIN rail active and reactive power transducer – unbalanced 3 wires three-phase connection (ARON)

    • Three-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Two analog output
    • Insulation 4kV
  • MT-PAR41

    DIN rail active and reactive power transducer – balanced 4 wires three-phase connection

    • Three-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Two analog output
    • Insulation 4kV
  • MT-PAR43

    DIN rail active and reactive power transducer – unbalanced 4 wires three-phase connection

    • Three-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Two analog output
    • Insulation 4kV
  • MT-Pdc

    DIN rail power transducer for D.C. systems

    • One channel 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 2kV
  • MT-PF1

    DIN rail power factor transducer – single phase connection

     

    • Single-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 4kV

     

  • MT-PF256

    DIN rail power factor transducer with high sampling – single phase connection

     

    • Single-phase 500V 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 4kV
  • MT-PF31

    DIN rail power factor transducer – balanced 3 wires three-phase connection

     

    • Three-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 4kV

  • MT-PF32

    DIN rail power factor transducer – unbalanced 3 wires three-phase connection (ARON)

    • Three-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 4kV
  • MT-PF41

    DIN rail power factor transducer – balanced 4 wires three-phase connection

    • Three-phase 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 4kV
1 2 3 4 5 6 7 8 15 16 17