E101U
DIN rail I/O universal module with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- A configurable input: analog signal – temperature sensor – resistance
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102P
DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two analog inputs
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102Pt
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102R
DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two inputs: resistances or potentiometers
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E742002AN-1
Digital indicator with 14 analog inputs – 72×144 – with ALARMS
- Accuracy: 0,5%
- Inputs: 0 … ±10V – 0 … ±5V – 0 … ± 60mV
- Insulation: 2kV
- RS485 ModBus RTU serial interface
- Alarms outputs
-
E742002AN-3
Digital indicator with 14 analog inputs – 72×144 – with ALARMS
- Accuracy: 0,5%
- Inputs: 0 … ±20mA – 4 … 20mA
- Insulation: 2kV
- RS485 ModBus RTU serial interface
- Alarms outputs
-
E742002AN-31
Digital indicator with 14 analog inputs – 72×144 – with ALARMS
- Accuracy: 0,5%
- Inputs: According to your needs
- Insulation: 2kV
- RS485 ModBus RTU serial interface
- Alarms outputs
-
NI-DT1
Valves control transducer – current generator
- Accuracy 0,5%
- Active analog output ± 200 mAdc max
- Insulation 2kV
- Aux. power supply: 230Vac
-
NI-DT2
Valves control transducer – current generator
- Accuracy 0,5%
- Active analog output ± 200 mAdc max
- Insulation 2kV
- Aux. power supply: 230Vac
-
E101U-E
DIN rail I/O universal module with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- A configurable input: analog signal – temperature sensor – resistance
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102P-E
DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two analog inputs
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102Pt-E
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc