3.2 Analog I / O modules-temperatures-resistors with RS485 and ethernet

Showing 1–12 of 50 results

  • E101U

    DIN rail I/O universal module with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • A configurable input: analog signal – temperature sensor – resistance
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102P

    DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102Pt

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E102R

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: resistances or potentiometers
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E742002AN-1

    Digital indicator with 14 analog inputs – 72×144 – with ALARMS

    • Accuracy: 0,5%
    • Inputs:  0 … ±10V – 0 … ±5V – 0 … ± 60mV
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Alarms outputs
  • E742002AN-3

    Digital indicator with 14 analog inputs – 72×144 – with ALARMS

    • Accuracy: 0,5%
    • Inputs: 0 … ±20mA – 4 … 20mA
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Alarms outputs
  • E742002AN-31

    Digital indicator with 14 analog inputs – 72×144 – with ALARMS

    • Accuracy: 0,5%
    • Inputs: According to your needs
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Alarms outputs
  • NI-DT1

    Valves control transducer – current generator

    • Accuracy 0,5%
    • Active analog output ± 200 mAdc max
    • Insulation 2kV
    • Aux. power supply: 230Vac
  • NI-DT2

    Valves control transducer – current generator

    • Accuracy 0,5%
    • Active analog output ± 200 mAdc max
    • Insulation 2kV
    • Aux. power supply: 230Vac
  • E101U-E

    DIN rail I/O universal module with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • A configurable input: analog signal – temperature sensor – resistance
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102P-E

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Pt-E

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

1 2 3 4 5