DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two analog outputs (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two analog outputs (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two thermocouple inputs: J – K – R – S – T – B – E – N
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two thermocouple inputs: J – K – R – S – T – B – E – N
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc