Inputs from temperature sensors 1 or 2 outputs - RS485 - ethernet

Showing 1–12 of 20 results

  • E102Pt

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E102Pt-E

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102Pt-2i

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102Pt-2E

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two analog outputs (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102Pt-2iE

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104Pt

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E104Pt-E

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E104Pt-2i

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E104Pt-2E

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two analog outputs (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104Pt-2iE

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102TC

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E102TC-E

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

1 2