Resistance or potentiometer inputs 1 or 2 outputs - RS485 - ethernet

Showing all 10 results

  • E102R

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: resistances or potentiometers
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102R-E

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: resistances or potentiometers
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102R-2i

    DIN rail I/O module for resistnces or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: resistances or potentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102R-2E

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: resistances or potentiometers
    • Two analog outputs (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102R-2iE

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: resistances orpotentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104R

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four inputs: resistances or potentiometers
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E104R-E

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: resistances or potentiometers
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104R-2i

    DIN rail I/O module for resistnces or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four inputs: resistances or potentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E104R-2E

    Modulo I/O per per resistenze o potenziometri da guida DIN con interfaccia seriale RS485 ModBus RTU e interfaccia Ethernet ModBus TCP/IP

    • Precisione 0,2% f.s.
    • Interfaccia Seriale RS485 ModBus RTU
    • ModBus TCP/IP su Ethernet
    • Quattro ingressi: resistenza o potenziometro
    • Due uscite analogiche attive o passive
    • Due uscite allarmi
    • SD card per log dati
    • Alimentazione: 18…48 Vac/dc
  • E104R-2iE

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: resistances orpotentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc