ID33009 is a 3 digit digital panel indicator (dimensions: 72 x 36 mm) suitable for reading a voltage, current and frequency of a single-phase line. ID33009 is the ideal solution for any type of system, application or panel where there is a need to display voltage, current and frequency with precision (accuracy class 0,5%) and reliability. The ESAM digital indicators allow you to set a series of useful functions such as: arbitrary scaling of the measurement, sign suppression, hold function, alternative scaling, decimal point position, etc. The instrument’s auxiliary power supply allows it to be used both in systems powered by mains voltage, thanks to an extended range power supply 60 … 265Vac / 80 … 300Vdc, and in systems powered at low voltage by having a extended range 12 … 60 Vac – 12 … 80Vdc (option).

Range types for models:

ID33009-01    500V/ 5A /99.9Hz
ID33009-02    500V/10A/99.9Hz
ID33009-03    500V/ 1A /99.9Hz
ID33009-11    100V/ 5A /99.9Hz
ID33009-12    100V/10A/99.9Hz
ID33009-13    100V/ 1A /99.9Hz

Digital indicator for alternating voltage, current and frequency – 72×36 – 3 digits

  • Accuracy: 0,5%
  • Inputs: 500V – 9,9A – 99.9Hz 
  • Insulation: 2kV

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E101A

    Single-phase network analyzer for DIN rail with RS485 ModBus RTU serial interface and analog outputs

     

    • Single-phase 10A
    • Accuracy 0,2% of f.s.
    • RS485 ModBus RTU serial interface
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc 
  • ESK 31.3

    Cable or bus bar current transformer

    • Accuracy: 1% o 0,5%
    • Cable dimension: 26 mm
    • Bus bar dimension: 30 x 10 mm
    • Range: 50 … 400A
  • MT-PACV256

    DIN rail voltage, current and active power transducer with high sampling – single phase insertion

    • Single-phase 500V 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 ModBus RTU Serial Interface
    • Three analog outputs
    • Insulation 4kV

You may also like…

  • SID96MP1

    Digital indicator for direct voltage – 96×48 – 4 digits with ALARMS

    • Accuracy: 0,2%
    • Input: ± 19.99mV … ± 1999V
    • Insulation: 2kV
  • ETP1043U3

    HMI touch panel – 4,3″ with ModBus RTU and ModBus TCP/IP interfaces

    • Touch panel
    • RS485 ModBus RTU
    • ModBus TCP/IP su Ethernet
    • Aux. power supply 12…36Vdc
    • Software PLC on board

     

     

     

  • 3ID9XX/XX

    Multiple digital indicator with three displays according to your needs – 96×96

    • Accuracy: 0,2% or 0,5%
    • Inputs: 3 – 3 ½ – 4 cifre
    • Insulation: 2kV