MT-UN43 is a universal transducer, suitable for balanced 4 wires three-phase line, which converts the signal taken from the system (voltage, current, power, etc.) into an analog process signal (0 … 5mA – 0..20mA – 4 … 20mA – 0 … 10V etc.) suitable for acquisition by PLC or data management systems. The MT-UN43 transducer is the ideal solution for all types of systems and thanks to its flexibility, it can be easily introduced into the system through rapid and independent programming. It’s able to guarantee high insulation (4kV) between input and output and to perform measurements with acquisition times <50 msec (option), high accuracy class (0.5% or 0.2%) and is capable of to manage signals up to 500V – 10A. It’s equipped with a RS485 ModBus RTU serial interface which allows remote monitoring of all measurement parameters and allows configuration of the same through PrTrasd software with which it is possible to set: type of input (voltage, current, active reactive or apparent power , power factor, etc.), input range, output range and output type, test the outputs, set filter on the measurements, etc. The desired quantity will be associated with the analog output, but all other measurements can be read via the ModBus serial interface. The auxiliary power supply of the instrument allows it to be used both in systems powered by mains voltage and in systems powered at 24Vdc by having an 18 … 60 Vac / dc extended range power supply.

Universal DIN rail converter – unbalanced three-phase 4 wires connection

  • Three-phase – 500V 10A max
  • Accuracy0,5%
  • RS485 ModBus RTU Serial interface
  • Analog output
  • Insulation 4kV

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • EWSK 40N

    Primary wound current transformer

    • Accuracy: 0,5%
    • Range: 40 … 50A
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc
  • VN20-N

    Measuring voltage transformer with 2 isolated poles

    • Accuracy: 0,5%
    • Burden: 20VA
    • Range: 100 … 1000V

You may also like…

  • M403-E

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two alarms outputs
  • E2002

    Rear panel network analyzer for three-phase (3-4 wires or ARON) connection

    • Three-phase with display
    • Accuracy 0,5% of f.s.
    • RS485 ModBus RTU Serial interface
    • Two alarms outputs
  • E101A-E

    Single-phase network analyzer for DIN rail with RS485 ModBus RTU serial interface, ModBus TCP/IP on Ethernet interface and analog outputs

    • Single-phase 10A
    • Accuracy 0,2% of f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc