SID98MPT is an 8 digits digital panel indicator (96 x 96 mm) suitable for reading a voltage or direct current and designed to manage process signals (0 … ± 10V – 0 … ± 5V – 4 .. .20mA – 0 … 20mA etc.) and provides the integrated measurement of the measured parameters. SID98MPT is the ideal solution for any type of system, application or switchboard where there is a need to display a process signal (voltage or direct current) with precision (Cl. 0.1%) and reliability, for ex. coming from a sensor, from a PLC output or from a transducer (e.g. MT-UN1, MT-Ca, MT-Pdc, MT-PA1, MT-RC1 etc.) and display the associated engineering quantity (e.g. Pa, RPM, kA, W, Bar etc.). It’s possible to set a series of useful functions using the frontal buttons, such as: access code, minimum or maximum alarms, measurement update filter, peak measurements, measurement scaling, etc. It’s also equipped with four relay outputs, a configurable analog output, a RS485 ModBus RTU serial output and a sensor power supply output. It can be supplied with one or two input channels. The auxiliary power supply of the instrument allows it to be used both in systems powered by mains voltage (115/230 Vac) and in systems powered by low voltage with an extended range power supply 20…60Vac/dc (option).
Inputs types for models:
SID98MPT-1 Input1: 0 … ±10V
SID98MPT-11 Input1: 0 … ±10V Input 2: 0 … ±10V
SID98MPT-3 Input1: 0 … ±20 / 4…20mA
SID98MPT-33 Input1: 0 … ±20 / 4…20mA Input 2: 0 … ±20 / 4…20mA
SID98MPT-31 Input1: 0 … ±20 / 4…20mA Input 2: 0 … ±10V
Integration examples:
– power (kW, kVAR) => energy (kWh, kVARh) – volume flow (mc / min) => volume (mc) – speed => length (m)
Digital indicator (INTEGRATOR / TOTALIZER) for high precision process signals – 96×96 format – 8 digits with ALARMS
- Accuracy 0,1%
- Input: 99999999
- Integrated measurement
- Insulation 2kV
- RS485 ModBus RTU serial interface
- Analog output
Data Sheet
User Manual
Catalog
Software
Recommended accessories…
You may also like…
-
SID98MPT-P
Digital indicator (INTEGRATOR / TOTALIZER) for high precision potentiometers signals – 96×96 format – 8 digits with ALARMS
- Accuracy 0,1%
- Input: 99999999
- Integrated measurement
- Insulation 2kV
- RS485 ModBus RTU serial interface
- Analog output
-
SID98MPT-MV
Digital indicator (INTEGRATOR / TOTALIZER) for high precision mV (from SHUNTS) signals – 96×96 format – 8 digits with ALARMS
- Accuracy 0,1%
- Input: 99999999
- Integrated measurement
- Insulation 2kV
- RS485 ModBus RTU serial interface
- Analog output
-
E101U-E
DIN rail I/O universal module with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- A configurable input: analog signal – temperature sensor – resistance
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc