MT-CV256 is a voltage and current transducer, suitable for single-phase systems, which converts the signal taken from the system into an analog process signal (0 … 5mA – 0..20mA – 4 … 20mA – 0 … 10V etc.) suitable for acquisition through PLC or data management systems. The MT-CV256 transducer is a high sampling device (256 samples per network cycle) indispensable in systems with distorted or partialized waveforms, it’s able to ensure high insulation (4kV) between input and output and and to perform measurements with acquisition times <50 msec (option), high accuracy class (0.5% or 0.2%) and manages signals up to 500V – 10A. It can be supplied with RS485 ModBus RTU serial interface which provides remote monitoring of all measurement and configuration parameters. When supplied with a serial interface, the transducer can be configured using PrTrasd software with which it is possible to set the input range, output range, perform output tests, etc. The auxiliary power supply allows it to be used both in systems powered by mains voltage and in systems powered at 24Vdc by having an 18 … 60 Vac / dc extended range power supply on board.

DIN rail voltage and current transducer with high sampling – single phase insertion

  • Single-phase 500V 10A max
  • Accuracy 0,5%
  • High sampling
  • RS485 ModBus RTU Serial Interface
  • Two analog outputs
  • Insulation 4kV 

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E-CONNECT

    Gateway RS485 ModBus RTU – ModBus ModBus TCP/IP

    • RS485 ModBus RTU Serial interface
    • ModBus TCP/IP on Ethernet
    • Aux. power supply: 18…48Vac/dc

     

  • ESK 41.4

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 32 mm
    • Bus bar dimension: 40 x 10 mm
    • Range: 250 … 800A
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc

You may also like…

  • MT-UN41

    Universal DIN rail converter – balanced three-phase 4 wires connection

    • Three-phase – 500V 10A max
    • Accuracy0,5%
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulation 4kV
  • MT-CaFP

    DIN rail transducer for alternating current with energy direction – aux. power supply execution

    • Single-phase 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 Serial interface
    • Analog output
    • Insulation 4kV
  • MT-C3

    DIN rail transducer for alternating current – aux. power supply execution

    • Three-phase 10A max
    • Accuracy0,5%
    • RS485 Serial interface
    • Analog output
    • Insulation 4kV