MT-C3 is an alternating current transducer that converts the signal coming from a CT or field measurement into an analog process signal (0 … 5mA – 0..20mA – 4 … 20mA – 0 … 10V etc.) suitable for acquisition by PLC or data management systems. The MT-C3 transducer has 3 measurement channels to read the current of a three-phase line. It’s able to guarantee high insulation (4kV) between input and output and to perform measurements with acquisition times <100 msec (option), high accuracy class (0.5% or 0.2%) by managing signals up to 10A. It can be supplied with a RS485 ModBus RTU serial interface that allows remote monitoring of all measurement and configuration parameters. When supplied with a serial interface, the transducer can be configured using PrTrasd software with which it is possible to set the input range, output range, perform output tests, etc. The auxiliary power supply allows it to be used both in systems powered by mains voltage and in systems powered at 24Vdc by having an 18 … 60 Vac / dc extended range power supply on board.

DIN rail transducer for alternating current – aux. power supply execution

  • Three-phase 10A max
  • Accuracy0,5%
  • RS485 Serial interface
  • Analog output
  • Insulation 4kV

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E-CONNECT

    Gateway RS485 ModBus RTU – ModBus ModBus TCP/IP

    • RS485 ModBus RTU Serial interface
    • ModBus TCP/IP on Ethernet
    • Aux. power supply: 18…48Vac/dc

     

  • ESK 61.4

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 44 mm
    • bus bar dimension: 63 x 10 mm
    • Range: 400 … 1500A
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc

You may also like…

  • MT-UN43

    Universal DIN rail converter – unbalanced three-phase 4 wires connection

    • Three-phase – 500V 10A max
    • Accuracy0,5%
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulation 4kV
  • MT-CV256

    DIN rail voltage and current transducer with high sampling – single phase insertion

    • Single-phase 500V 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 ModBus RTU Serial Interface
    • Two analog outputs
    • Insulation 4kV 
  • MT-CaFP

    DIN rail transducer for alternating current with energy direction – aux. power supply execution

    • Single-phase 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 Serial interface
    • Analog output
    • Insulation 4kV