MT-CaFP is an alternating current transducer that converts the signal from a CT or field measurement into an analog process signal (0 … 5mA – 0..20mA – 4 … 20mA – 0 … 10V etc.) suitable for acquisition by PLC or data management systems. The MT-CaFP transducer is a device that provides, in addition to the current measurement, the energy direction (supplied or withdrawn) thanks to the bidirectional output. It’s able to guarantee high insulation (4kV) between input and output and to perform measurements with acquisition times <100 msec (option), high accuracy class (0.5% or 0.2%) by managing signals up to 10A. It can be supplied with RS485 ModBus RTU serial interface which allows remote monitoring of all measurement and configuration parameters. When supplied with a serial interface, the transducer can be configured using PrTrasd software with which it is possible to set the input range, output range, perform output tests, etc. The auxiliary power supply allows it to be used both in systems powered by mains voltage and in systems powered at 24Vdc by having an 18 … 60 Vac / dc extended range power supply on board.

DIN rail transducer for alternating current with energy direction – aux. power supply execution

  • Single-phase 10A max
  • Accuracy 0,5%
  • High sampling
  • RS485 Serial interface
  • Analog output
  • Insulation 4kV

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E-CONNECT

    Gateway RS485 ModBus RTU – ModBus ModBus TCP/IP

    • RS485 ModBus RTU Serial interface
    • ModBus TCP/IP on Ethernet
    • Aux. power supply: 18…48Vac/dc

     

  • ESK 31.5

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Cable dimension: 28 mm
    • Bus bar dimension: 30 x 10 mm
    • Range: 100 … 200A
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc

You may also like…

  • MT-CV256

    DIN rail voltage and current transducer with high sampling – single phase insertion

    • Single-phase 500V 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 ModBus RTU Serial Interface
    • Two analog outputs
    • Insulation 4kV 
  • MT-C3

    DIN rail transducer for alternating current – aux. power supply execution

    • Three-phase 10A max
    • Accuracy0,5%
    • RS485 Serial interface
    • Analog output
    • Insulation 4kV
  • MT-C256

    DIN rail transducer for alternating current with high sampling – aux. power supply execution

    • Single-phase 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 Serial interface
    • Analog output
    • Insulation 4kV