Catalogo

  • M903

    Front panel (96×96 mm) multifunction meter, three-phase (3 – 4 wires or ARON) connection

     

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • Two alarms outputs
    • Touch buttons

     

  • M903-E

    Front panel (96×96 mm) multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two alarms outputs
    • Touch buttons
  • M903-M

    Front panel (96×96 mm) multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface

     

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two alarms outputs
    • Touch buttons

     

  • M903-R

    Front panel (96×96 mm) multifunction meter, three-phase (3 – 4 wires or ARON) connection

    • Three-phase with display
    • Accuracy: 0,2%
    • Input from Rogowski coil
    • Two alarms outputs
    • Touch buttons

     

  • M903-RE

    Front panel (96×96 mm) multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface

    • Three-phase with display
    • Accuracy: 0,2%
    • Input from Rogowski coil
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two alarms outputs
    • Touch buttons
  • M903-RM

    Front panel (96×96 mm) multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface

    • Three-phase with display
    • Accuracy: 0,2%
    • Input from Rogowski coil
    • RS485 ModBus RTU serial interface
    • Two alarms outputs
    • Touch buttons
  • MI48C

    Analog ammeter for A.C. signals – 48×48

    • Accuracy: 1,5%
    • Input: 1A … from CT / 5A
    • Scale: 90°
  • MT-AF

    DIN rail phase angle transducer for alternating current systems

     

    • Two inputs 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 4kV
  • MT-C

    DIN rail transducer for alternating current – selfpowered execution

     

    • Single-phase 10A max
    • Accuracy 0,5%
    • Analog output
    • Insulation 4kV
  • MT-CV256

    DIN rail voltage and current transducer with high sampling – single phase insertion

    • Single-phase 500V 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 ModBus RTU Serial Interface
    • Two analog outputs
    • Insulation 4kV 
  • MT-F

    DIN rail frequency transducer for alternating current systems

    • One channel 500V max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 4kV

     