3 Modules for industrial automation - control and communication

  • E102Pt

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E102Ptid

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102R

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs: resistances or potentiometers
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E104PD

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two analog inputs
    • Two digital inputs: NPN – PNP – Namur – Impulsi – Effetto hall – Encoder
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E106D

    DIN rail I/O module for digital signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E3000

    Interface with 3 analog outputs – RS485 ModBus RTU Serial interface

    • 3 analog outputs
    • Accuracy: 0,2%
    • Aux. power supply: 115/230Vac or 24Vdc
  • E742002AN-1

    Digital indicator with 14 analog inputs – 72×144 – with ALARMS

    • Accuracy: 0,5%
    • Inputs:  0 … ±10V – 0 … ±5V – 0 … ± 60mV
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Alarms outputs
  • E742002AN-3

    Digital indicator with 14 analog inputs – 72×144 – with ALARMS

    • Accuracy: 0,5%
    • Inputs: 0 … ±20mA – 4 … 20mA
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Alarms outputs
  • E742002AN-31

    Digital indicator with 14 analog inputs – 72×144 – with ALARMS

    • Accuracy: 0,5%
    • Inputs: According to your needs
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Alarms outputs
  • E804

    DIN rail I/O module for digital signals – RS485 ModBus RTU serial interface – Relays outputs

    • RS485 ModBus RTU Serial Interface
    • Four digital inputs
    • 3 NO/NC Relays outputs
    • 1 NO Relay output
    • Auxiliary power supply: 115/230Vac
  • E806

    DIN rail I/O module for digital signals – RS485 ModBus RTU serial interface – Relays outputs

    • RS485 ModBus RTU Serial Interface
    • Six digital inputs
    • 3 NO/NC Relays outputs
    • 3 NO Relay outputs
    • Auxiliary power supply: 115/230Vac
  • E810

    DIN rail I/O module for digital signals – RS485 ModBus RTU serial interface – Relays outputs

    • RS485 ModBus RTU Serial Interface
    • Six digital inputs
    • 3 NO/NC Relays outputs
    • 5 NO Relay outputs
    • Auxiliary power supply: 115/230Vac
1 2 3 4 5 7 8 9