Showing 85–96 of 99 results
-
E104R-2E
Modulo I/O per per resistenze o potenziometri da guida DIN con interfaccia seriale RS485 ModBus RTU e interfaccia Ethernet ModBus TCP/IP
- Precisione 0,2% f.s.
- Interfaccia Seriale RS485 ModBus RTU
- ModBus TCP/IP su Ethernet
- Quattro ingressi: resistenza o potenziometro
- Due uscite analogiche attive o passive
- Due uscite allarmi
- SD card per log dati
- Alimentazione: 18…48 Vac/dc
-
E102TCid-2iE
DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two inputs from thermocouples: types J – K – R – S – T – B – E – N
- Two insulated analog outputs with PID control
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104P-2iE
DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four analog inputs
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104Pt-2iE
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104R-2iE
DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: resistances orpotentiometers
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102TC
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two thermocouple inputs: J – K – R – S – T – B – E – N
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102TC-E
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two thermocouple inputs: J – K – R – S – T – B – E – N
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102TC-2i
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Two thermocouple inputs: J – K – R – S – T – B – E – N
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102TC-2E
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two thermocouple inputs: J – K – R – S – T – B – E – N
- Two analog outputs (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102TC-2iE
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two thermocouple inputs: J – K – R – S – T – B – E – N
- Two insulated analog outputs (loop powered or load independent)
- Two digital outputs (insulated from each other)
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104TC
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four thermocouple inputs: J – K – R – S – T – B – E – N
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104TC-E
DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four thermocouple inputs: J – K – R – S – T – B – E – N
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger