3 Modules for industrial automation - control and communication

  • E104R-2E

    Modulo I/O per per resistenze o potenziometri da guida DIN con interfaccia seriale RS485 ModBus RTU e interfaccia Ethernet ModBus TCP/IP

    • Precisione 0,2% f.s.
    • Interfaccia Seriale RS485 ModBus RTU
    • ModBus TCP/IP su Ethernet
    • Quattro ingressi: resistenza o potenziometro
    • Due uscite analogiche attive o passive
    • Due uscite allarmi
    • SD card per log dati
    • Alimentazione: 18…48 Vac/dc
  • E102TCid-2iE

    DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs from thermocouples: types J – K – R – S – T – B – E – N
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104P-2iE

    DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four analog inputs
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104Pt-2iE

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104R-2iE

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: resistances orpotentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102TC

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E102TC-E

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102TC-2i

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated  from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E102TC-2E

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Two analog outputs (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102TC-2iE

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104TC

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E104TC-E

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
1 2 3 5 6 7 8 9