Showing 25–36 of 99 results
-
ES104P
DIN rail expansion I/O module for analog signals
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four analog inputs
- Two analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: from TBUS
-
ES104Pt
DIN rail expansion I/O module for thermoresistances
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: from TBUS
-
ES104R
DIN rail expansion I/O module for resistances or potentiometers
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four inputs: 0…100kOhm
- Two analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: from TBUS
-
ES104TC
DIN rail expansion I/O module for themocouples
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- Four inputs from thermocouples: types J – K – R – S – T – B – E – N
- Two analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: from TBUS
-
ES106D
DIN rail expansion I/O module for digital signals
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
- Two analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: from TBUS
-
MT232485
RS232 – RS485 signal converter
- RS485 serial Interface
- RS232 serial interface
- Aux. power supply: 115/230Vac or 20…60Vac/dc
-
NI-DT1
Valves control transducer – current generator
- Accuracy 0,5%
- Active analog output ± 200 mAdc max
- Insulation 2kV
- Aux. power supply: 230Vac
-
NI-DT2
Valves control transducer – current generator
- Accuracy 0,5%
- Active analog output ± 200 mAdc max
- Insulation 2kV
- Aux. power supply: 230Vac
-
T-BUS
Accessory for T-BUS connection
- Compatible with all products in the E10X series
-
E101P-E
DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E101U-E
DIN rail I/O universal module with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- A configurable input: analog signal – temperature sensor – resistance
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E102P-E
DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two analog inputs
- Analog output (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc