3 Modules for industrial automation - control and communication

  • ES104P

    DIN rail expansion I/O module for analog signals

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four analog inputs
    • Two analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: from TBUS 
  • ES104Pt

    DIN rail expansion I/O module for thermoresistances

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: from TBUS
  • ES104R

    DIN rail expansion I/O module for resistances or potentiometers

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four inputs: 0…100kOhm
    • Two analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: from TBUS 
  • ES104TC

    DIN rail expansion I/O module for themocouples

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four inputs from thermocouples: types J – K – R – S – T – B – E – N
    • Two analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: from TBUS
  • ES106D

    DIN rail expansion I/O module for digital signals

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: from TBUS
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc
  • NI-DT1

    Valves control transducer – current generator

    • Accuracy 0,5%
    • Active analog output ± 200 mAdc max
    • Insulation 2kV
    • Aux. power supply: 230Vac
  • NI-DT2

    Valves control transducer – current generator

    • Accuracy 0,5%
    • Active analog output ± 200 mAdc max
    • Insulation 2kV
    • Aux. power supply: 230Vac
  • T-BUS

    Accessory for T-BUS connection

    • Compatible with all products in the E10X series
  • E101P-E

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E101U-E

    DIN rail I/O universal module with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • A configurable input: analog signal – temperature sensor – resistance
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102P-E

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
1 2 3 4 5 6 7 8 9