MT-C256 is an alternating current transducer that converts the signal coming from a CT or field measurement into an analog process signal (0 … 5mA – 0..20mA – 4 … 20mA – 0 … 10V etc.) suitable for acquisition by PLC or data management systems. The MT-C256 transducer is a high sampling device (256 sample per network cycle) indispensable in systems with distorted or partialized waveforms. It’s able to guarantee high insulation (4kV) between input and output and to perform measurements with acquisition times <100 msec (option), high accuracy class (0.5% or 0.2%) by managing signals up to 10A. It can be supplied with RS485 ModBus RTU serial interface which allows remote monitoring of all measurement and configuration parameters. When supplied with a serial interface, the transducer can be configured using PrTrasd software with which it is possible to set the input range, output range, perform output tests, etc. The auxiliary power supply of the instrument allows it to be used both in systems powered by mains voltage and in systems powered at 24Vdc by having an 18 … 60 Vac / dc extended range power supply on board.

DIN rail transducer for alternating current with high sampling – aux. power supply execution

  • Single-phase 10A max
  • Accuracy 0,5%
  • High sampling
  • RS485 Serial interface
  • Analog output
  • Insulation 4kV

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • EM3

    Cable or bus bar current transformer

    • Accuracy: 1%, 3% o 0,5%
    • Cable dimension: 23 mm
    • Bus bar dimension: 30 x 10 mm
    • Range: 100 … 400A
  • ESK 165.5

    Cable or bus bar current transformer

    • Accuracy: 0,5%
    • Bus bar dimension: 3 x 160 x 10 mm
    • Range: 1000 … 4000A
  • ESK 31.3

    Cable or bus bar current transformer

    • Accuracy: 1% o 0,5%
    • Cable dimension: 26 mm
    • Bus bar dimension: 30 x 10 mm
    • Range: 50 … 400A

You may also like…

  • MT-CaFP

    DIN rail transducer for alternating current with energy direction – aux. power supply execution

    • Single-phase 10A max
    • Accuracy 0,5%
    • High sampling
    • RS485 Serial interface
    • Analog output
    • Insulation 4kV
  • MT-Ca TRMS

    DIN rail transducer for TRMS alternating current – aux. power supply execution

    • Single-phase 10A max
    • Accuracy 0,5%
    • TRMS input
    • Analog output
    • Insulation 4kV 
  • MT-C3

    DIN rail transducer for alternating current – aux. power supply execution

    • Three-phase 10A max
    • Accuracy0,5%
    • RS485 Serial interface
    • Analog output
    • Insulation 4kV