MT-CdcTRMS is a TRMS direct current transducer that converts the current signal present in the system into an analog process signal (0 … 5mA – 0..20mA – 4 … 20mA – 0 … 10V etc.) suitable for the acquisition through PLC or data management systems. The MT-CdcTRMS transducer is the ideal solution for systems in which the waveforms are partialized as it measures the true effective value of the current. It’s able to guarantee high insulation (2kV) between input and output with acquisition times <50 msec (option), high precision class (0.5% or 0.2%) by managing signals up to 10A. It can be supplied with RS485 ModBus RTU serial interface which allows remote monitoring of all measurement and configuration parameters. When supplied with a serial interface, the transducer can be configured using PrTrasd software with which it is possible to set the input range, output range, perform output tests, etc. The auxiliary power supply of the instrument allows it to be used both in systems powered by mains voltage and in systems powered at 24Vdcby having an 18 … 60 Vac / dc extended range power supply on board.

DIN rail transducer for TRMS direct current – aux. power supply execution

  • One channel 10A max
  • Accuracy 0,5%
  • TRMS input
  • RS485 Serial interface
  • Analog output
  • Insulation 2kV

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E-CONNECT

    Gateway RS485 ModBus RTU – ModBus ModBus TCP/IP

    • RS485 ModBus RTU Serial interface
    • ModBus TCP/IP on Ethernet
    • Aux. power supply: 18…48Vac/dc

     

  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc
  • SHUNT-3

    SHUNT /60mV – /100mV – /150mV DIN Series

    • Accuracy: 0,5%
    • Output signal: 60mV – 100mV – 150mV
    • Range: 250…2500 A

You may also like…

  • MT-Pdc

    DIN rail power transducer for D.C. systems

    • One channel 500V 10A max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Insulation 2kV
  • MT-Cdc

    DIN rail transducer for direct current – aux. power supply execution

    • One channel 10A max
    • Accuracy 0,5%
    • RS485 Serial interface
    • Analog output
    • Insulation 2kV
  • E101P-2E

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog outputs (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc