Catalogo

  • MT-Vdc Z

    DIN rail transducer for D.C. voltage with extended range – aux. power supply execution

    • One channel 500V max
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulaion 2kV

     

  • SID98MP-TC

    Digital indicator for high precision thermocouple measurements – dimensions 96×96  – 8 digits with ALARMS

    • Accuracy: 0,1%
    • Input:   99999999
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Analog output
  • E102TCid-2iE

    DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs from thermocouples: types J – K – R – S – T – B – E – N
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104P-2iE

    DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four analog inputs
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104Pt-2iE

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104R-2iE

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: resistances orpotentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E72VT

    Analog varmeter for A.C. signals – 72×72 with accessory –  4 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • E72WT

    Analog wattmeter for A.C. signals – 72×72 with accessory –  4 wires THREE-PHASE connection

    • Accuracy: 1,5%
    • Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
    • Scale: 90°
  • EM1

    Cable current transformer

    • Accuracy: 1%, 3% o 0,5% 
    • Cable dimension: 22 mm
    • Range: 30 … 250A
  • ID33001-20…25

    Digital indicator for analog process signals (direct voltage) – 72×36 – 3 digits

    • Accuracy: 0,2%
    • Input: ± 999
    • Insulation: 2kV

     

     

  • ID43001-20…25

    Digital indicator for analog process signals (direct voltage) – 96×48 – 3 digits

    • Accuracy: 0,2%
    • Input: ± 999
    • Insulation: 2kV

     

     

  • ID73001-20…25

    Digital indicator for analog process signals (direct voltage) – 72×72 – 3 digits

    • Accuracy: 0,2%
    • Input: ± 999
    • Insulation: 2kV

     

     

1 2 3 49 50 51 52 53 54 55 59 60 61