Showing 601–612 of 724 results
-
E102TCid-2E
DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Two inputsfrom thermocouples: types J – K – R – S – T – B – E – N
- Two analog outputs with PID control
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104P-2E
DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four analog inputs
- Two analog outputs (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104Pt-2E
DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet
- Accuracy: 0,2% f.s.
- RS485 ModBus RTU serial interface
- ModBus TCP/IP on Ethernet
- Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
- Two analog outputs (loop powered or load independent)
- Two digital outputs
- SD memory card for datalogger
- Aux. power supply: 18…48 Vac/dc
-
E104R-2E
Modulo I/O per per resistenze o potenziometri da guida DIN con interfaccia seriale RS485 ModBus RTU e interfaccia Ethernet ModBus TCP/IP
- Precisione 0,2% f.s.
- Interfaccia Seriale RS485 ModBus RTU
- ModBus TCP/IP su Ethernet
- Quattro ingressi: resistenza o potenziometro
- Due uscite analogiche attive o passive
- Due uscite allarmi
- SD card per log dati
- Alimentazione: 18…48 Vac/dc
-
E72VS
Analog varmeter for A.C. signals – 72×72 with accessory – 4 wires THREE-PHASE connection
- Accuracy: 1,5%
- Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Scale: 90°
-
E72WS
Analog wattmeter for A.C. signals – 72×72 with accessory – 4 wires THREE-PHASE connection
- Accuracy: 1,5%
- Inputs: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Scale: 90°
-
E96PS
Analog cosphimeter for A.C. signals – 96×96 with accessory – 4 wires THREE-PHASE conection
- Accuracy: 1,5%
- Input: 100V … from VT xx/ 100V / 1A … from CT xx/5 A
- Range: 0.5 lead / 1 / 0.5 lad (others on request)
- Scale: 90°
-
ID34008
Digital indicator for tachometric frequency – 72×36 – 4 digits
- Accuracy: 0,2%
- Input: 9.999 RPM… 9999 RPM
- Insulation: 2kV
-
ID95001-20…25
Digital meter for process signals (D.C. voltage) with high resolution – dimensions 96×96 – 5 digit with RS485 Modbus RTU serial interface
- Accuracy: 0,2%
- Input: 99999
- Insulation: 2kV
-
M403
DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection
- Three-phase with display
- Accuracy: 0,2% f.s.
- Two alarms outputs
-
MT-Cdc Z
DIN rail transducer for direct current with extendedrange – aux. power supply execution
- One channel 10A max
- Accuracy 0,5%
- RS485 Serial interface
- Analog output
- Insulation 2kV