Catalogo

  • ID93001-20…25

    Digital indicator for analog process signals (direct voltage) – 96×96 – 3 digits

    • Accuracy: 0,2%
    • Input: ± 999
    • Insulation: 2kV

     

     

  • ID95003-20…25

    Digital meter for process signals (D.C.) with high resolution – dimensions 96×96 – 5 digit with RS485 Modbus RTU serial interface

    • Accuracy:  0,2%
    • Input:   99999
    • Insulation: 2kV
  • IDM3001-20…25

    Digital indicator for analog process signals (direct voltage) – 4 DIN MODULES – 3 digits

    • Accuracy: 0,2%
    • Input: ± 999
    • Insulation: 2kV

     

  • M1 72144

    IP 54 plumbable splashproof transparent cover – dimensions 72×144

    • Dimensions: 72×144 mm
    • Protection degree: IP54
  • M1 7272

    IP 54 plumbable splashproof transparent cover – dimensions 72×72

    • Dimensions: 72×72 mm
    • Protection degree: IP54
  • M1 9648

    IP 54 plumbable splashproof transparent cover – dimensions 96×48

    • Dimensions: 96×48 mm
    • Protection degree: IP54
  • M1 9696

    IP 54 plumbable splashproof transparent cover – dimensions96x96

    • Dimensions: 96×96 mm
    • Protection degree: IP54
  • M403-M

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface

     

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two alarms outputs

     

  • MT-CdcTRMS

    DIN rail transducer for TRMS direct current – aux. power supply execution

    • One channel 10A max
    • Accuracy 0,5%
    • TRMS input
    • RS485 Serial interface
    • Analog output
    • Insulation 2kV
  • MT-VdcTRMS

    DIN rail transducer for TRMS D.C. voltage – aux. power supply execution

    • One channel 500V max
    • Accuracy 0,5%
    • TRMS input
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulaion 2kV
  • SID98MP-MV

    Digital indicator for high precision mV measurements – dimensions 96×96  – 8 digits with ALARMS

    • Accuracy: 0,1%
    • Input:   99999999
    • Insulation: 2kV
    • RS485 ModBus RTU serial interface
    • Analog output
  • E102TC

    DIN rail I/O module for thermocouple with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two thermocouple inputs: J – K – R – S – T – B – E – N
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

1 2 3 50 51 52 53 54 55 56 59 60 61