1 Electric measures and energy management

  • MT-S4

    Summing for four-channel process signals with RS485 ModBus RTU serial interface

    • Four analog signals
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Configurable inputs range
  • MT-S6

    Summing for six-channel process signals with RS485 ModBus RTU serial interface

    • Six analog signals
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Configurable inputs range
  • MT-S8

    Summing for eight-channel process signals with RS485 ModBus RTU serial interface

    • Eight analog signals
    • Accuracy 0,5%
    • RS485 ModBus RTU Serial Interface
    • Analog output
    • Configurable inputs range
  • MT-UN1

    Convertitore universale da guida DIN – inserzione monofase

    • Monofase 500V 10A max
    • Precisione 0,5%
    • Interfaccia Seriale RS485 ModBus RTU
    • Uscita analogica attiva
    • Isolamento 4kV
  • MT-UN31

    Universal DIN rail converter – balanced three-phase 3 wires connection

    • Three-phase – 500V 10A max
    • Accuracy0,5%
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulation 4kV
  • MT-UN32

    Universal DIN rail converter – unbalanced three-phase 3 wires connection  (ARON)

    • Three-phase – 500V 10A max
    • Accuracy0,5%
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulation 4kV
  • MT-UN41

    Universal DIN rail converter – balanced three-phase 4 wires connection

    • Three-phase – 500V 10A max
    • Accuracy0,5%
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulation 4kV
  • MT-UN43

    Universal DIN rail converter – unbalanced three-phase 4 wires connection

    • Three-phase – 500V 10A max
    • Accuracy0,5%
    • RS485 ModBus RTU Serial interface
    • Analog output
    • Insulation 4kV
  • MT-V

    DIN rail transducer for alternating voltage – self-powered execution

    • Single-phase 500V max
    • Accuracy 0,5%
    • Analog output
    • Insulaion 4kV
  • NI-DT1

    Valves control transducer – current generator

    • Accuracy 0,5%
    • Active analog output ± 200 mAdc max
    • Insulation 2kV
    • Aux. power supply: 230Vac
  • NI-DT2

    Valves control transducer – current generator

    • Accuracy 0,5%
    • Active analog output ± 200 mAdc max
    • Insulation 2kV
    • Aux. power supply: 230Vac
  • PR-1

    Voltage divider

    • Continuous overload: 1,2 Vn
    • Range: 600 … 2000V