3 Modules for industrial automation - control and communication

  • E101U-2iE

    DIN rail I/O universal module with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • A configurable input: analog signal – temperature sensor – resistance
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102P-2iE

    DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Pid-2iE

    DIN rail I/O module with PID regulation for analog signals – RS485 ModBus RTU serial interface and ModBus TCP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Pt-2iE

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102Ptid-2iE

    DIN rail thermoregulator for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102R-2iE

    DIN rail I/O module for resistances or potentiometers with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two inputs: resistances orpotentiometers
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E104PD-2iE

    DIN rail I/O module for analog and digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two analog inputs
    • Two inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two insulated analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E106D-2iE

    DIN rail I/O module for digital signals with RS485 ModBus RTU serial interface and Ethernet output with ModBus TCP/IP protocol

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • 6 inputs: NPN – PNP – Namur – Pulses – Hall sensors – Encoder
    • Two insulated analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E101P-2iE

    DIN rail insulator for analog signals with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc
  • E102TCid

    DIN rail thermoregulator for thermocouples with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two inputs from thermocouples: types J – K – R – S – T – B – E – N
    • Analog output with PID control
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

  • E104P

    DIN rail I/O module for analog signals with RS485 ModBus RTU serial interface

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Four analog inputs
    • Analog output (loop powered or load independent)
    • Two digital outputs
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

  • E104Pt

    DIN rail I/O module for thermoresistances with RS485 ModBus RTU serial interface and ModBus TCP/IP on Ethernet

    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Four inputs: Pt100 – Pt1000 – Pt500 – Ni100
    • Two insulated analog outputs (loop powered or load independent)
    • Two digital outputs (insulated from each other)
    • SD memory card for datalogger
    • Aux. power supply: 18…48 Vac/dc

     

     

1 2 3 4 5 6 7 8 9