E742002 is a fron panel network analyzer (72×144 mm) suitable for measuring electrical parameters of an A.C. line in all configurations (3-4 wires or ARON). It’s powered by a separate voltage input (galvanically isolated) and has a current input capable of measuring from 0.05 to 5 A direct or through CT (/ 5A or / 1A) and through external VT. It is also available in a self-powered version and is equipped with a 16×2 LCD display capable of guaranteeing excellent display of the parameters in all application needs. It’s equipped with two digital outputs that can be used as alarm or pulse outputs (for energy) and an insulated RS485 ModBus RTU serial output which allows remote monitoring of all measurement and configuration parameters. The E742002 analyzer is the ideal tool for displaying all the electrical parameters of a three-phase line (voltages, currents, active – reactive – apparent powers, power factor, energies, etc.) and is very simple to configure. The E742002 network analyzer can also be connected to the E3000 module equipped with 3 analog outputs (4 … 20mA – 0 … 10mA – 0 … 5mA – 0 … 10V etc.) which can be associated with the measurements made by the analyzer to repeat the measured signal to acquisition systems such as PLC, other instruments, industrial PCs etc.

Front panel (72 x 144 mm) network analyzer for three-phase (3-4 wires or ARON) connection

  • Three-phase with display
  • Accuracy 0,5% of f.s.
  • RS485 ModBus RTU Serial interface
  • Two alarms outputs

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • E-CONNECT

    Gateway RS485 ModBus RTU – ModBus ModBus TCP/IP

    • RS485 ModBus RTU Serial interface
    • ModBus TCP/IP on Ethernet
    • Aux. power supply: 18…48Vac/dc

     

  • E3000

    Interface with 3 analog outputs – RS485 ModBus RTU Serial interface

    • 3 analog outputs
    • Accuracy: 0,2%
    • Aux. power supply: 115/230Vac or 24Vdc
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc

You may also like…

  • M903-M

    Front panel (96×96 mm) multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface

     

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • Two alarms outputs
    • Touch buttons

     

  • E92002

    Front panel (96 x 96 mm) network analyzer for three-phase (3-4 wires or ARON) connection

    • Three-phase with display
    • Accuracy 0,5% of f.s.
    • RS485 ModBus RTU Serial interface
    • Two alarms outputs