M403-BL is a DIN RAIL multifunction analyzer suitable for three-phase (3-4 wires or ARON) connection. It’s self-powered (from the measurement signal) and has a current input capable of measuring from 0.05 up to 63 A without the aid of external current transformers. However, it is possible to set CT and VT ratios at will for higher currents and voltages. It’s designed for all those applications where there is no need to view the parameters on site, but monitoring via serial interfaces is required. It’s equipped with two digital outputs which can be used as alarm or pulse outputs (for energy), a RS485 ModBus RTU serial interface and a ModBus TCP/IP Ethernet output which allows remote monitoring of all measurement and configuration parameters. M403-BL is the ideal instrument for monitor all electric parameters of a three-phase line (voltages, currents, frequency, active – reactive – apparent powers, energies, phase angle, etc.) and in addition to RMS measurements it also provides the fundamental measurements (according to the IEEE 1459-10 standards).

DIN RAIL multifunction meter, three-phase (3- 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface

  • Three-phase without display
  • Accuracy 0,2% f.s.
  • RS485 ModBus RTU serial interface
  • ModBus TCP/IP on Ethernet
  • Two alarms outputs

Data Sheet

User Manual

Catalog

Software

Recommended accessories…

Accessori consigliati

  • EM3

    Cable or bus bar current transformer

    • Accuracy: 1%, 3% o 0,5%
    • Cable dimension: 23 mm
    • Bus bar dimension: 30 x 10 mm
    • Range: 100 … 400A
  • ESR 20.3

    Cable or bus bar current transformer

    • Accuracy: 1% o 3%
    • Cable dimension: 21 mm
    • Range: 50 … 250A
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc

You may also like…

  • M403

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection

     

     

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • Two alarms outputs

     

     

     

  • E2002BL

    Rear panel network analyzer for three-phase (3-4 wires or ARON) connection

    • Three-phase without display
    • Accuracy 0,5% of f.s.
    • RS485 ModBus RTU Serial interface
    • Two alarms outputs
  • E1200

    High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection

    • Three-phase 3-4 eires or ARON
    • Accuracy 0,2% of reading (from 5 to 100% of f.s.)
    • RS485 ModBus serial interface
    • ModBus TCP/IP on Ethernet (with web server) 
    • Energies measures
    • Harmonic analysis up to 64° harmonic