E2002BL is a DIN rail network analyzer suitable for measuring electrical parameters of an A.C. line in all configurations (3-4 wires or ARON). It’s powered by a separate voltage input (galvanically isolated) and has a current input capable of measuring from 0.05 to 5 A direct or through CT (/ 5A or / 1A) and through external VT. It is also available in a self-powered version and it’s designed for all those applications where there is no need to display the parameters on site, but monitoring the data via the serial interface is sufficient. The E2002 analyzer is the ideal tool for monitoring all the electrical parameters of a three-phase line (voltages, currents, active – reactive – apparent powers, power factor, energies, etc.) and is very simple to configure. The E2002 network analyzer can also be connected to the E3000 module equipped with 3 analog outputs (4 … 20mA – 0 … 10mA – 0 … 5mA – 0 … 10V etc.) which can be associated with the measurements made by the analyzer to repeat the measured signal to acquisition systems such as PLC, other instruments, industrial PCs etc.

Rear panel network analyzer for three-phase (3-4 wires or ARON) connection

  • Three-phase without display
  • Accuracy 0,5% of f.s.
  • RS485 ModBus RTU Serial interface
  • Two alarms outputs

Recommended accessories…

Accessori consigliati

  • E-CONNECT

    Gateway RS485 ModBus RTU – ModBus ModBus TCP/IP

    • RS485 ModBus RTU Serial interface
    • ModBus TCP/IP on Ethernet
    • Aux. power supply: 18…48Vac/dc

     

  • E3000

    Interface with 3 analog outputs – RS485 ModBus RTU Serial interface

    • 3 analog outputs
    • Accuracy: 0,2%
    • Aux. power supply: 115/230Vac or 24Vdc
  • MT232485

    RS232 – RS485 signal converter

    • RS485 serial Interface
    • RS232 serial interface
    • Aux. power supply: 115/230Vac or 20…60Vac/dc

You may also like…

  • M403-E

    DIN RAIL multifunction meter, three-phase (3 – 4 wires or ARON) connection with RS485 ModBus RTU serial interface and ModBus TCP/IP Ethernet interface

    • Three-phase with display
    • Accuracy: 0,2% f.s.
    • RS485 ModBus RTU serial interface
    • ModBus TCP/IP on Ethernet
    • Two alarms outputs
  • E1200

    High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection

    • Three-phase 3-4 eires or ARON
    • Accuracy 0,2% of reading (from 5 to 100% of f.s.)
    • RS485 ModBus serial interface
    • ModBus TCP/IP on Ethernet (with web server) 
    • Energies measures
    • Harmonic analysis up to 64° harmonic
  • E1100

    High accuracy rear panel network analyzer, three-phase (3-4 wires or ARON) connection

     

    • Three-phase 3-4 eires or ARON
    • Accuracy 0,2% of reading (from 5 to 100% of f.s.)
    • RS485 ModBus serial interface
    • Harmonic analysis up to 64° harmonic